ea0085p52 | Diabetes 2 | BSPED2022

Review of glycaemic control following change from standardised insulin pump to hybrid closed loop

Yawar Saad , Regan Fiona

Introduction: Hybrid closed loop pumps (HCL) incorporate insulin pumps (IPs) with continuous glucose monitoring (CGM). Basal and bolus insulin release can be algorithmically adjusted in real-time enabling some automated insulin changes between meals according to set parameters. We reviewed the glycaemic control of patients with T1D cared for at the Evelina who had upgraded from IP to HCL between October 2020 and January 2022.Methods: As per standard care...